Products
|
|
Blocks Yak - 41/100 pair Terminal Block |
|
|
|
Technical Specification
Mechanical |
Test Name |
Test Requirements |
Tensile |
0.35mm / >20 N (Vertical) / >3N (Horizontal) |
Torsion |
0.50mm / >40N (Vertical) / >6N (Horizontal) |
Bending |
0.60mm / >50N (Vertical) / >8N (Horizontal) |
|
|
|
Electrical
Test Name |
Test Values ∆R |
Norms |
Connection Resistance |
< 1 mΩ
≤ 2.5 mΩ (per contact point
≤ 7.5 mΩ total) |
ASTM B539-96, IEC 60 512-2-2a |
Vibration |
< 1 mΩ, ≤ 2.5 mΩ |
ASTM B539-96, IEC 68-2-6 |
Insulation Resistance |
> 50 GΩ (50x109 Ω ) |
IEC 60 512-2-3a |
Dielectric Strength |
≥ 2 kVAC x 60sec |
IEC 60 512-2-4a |
High Voltage Surge |
1.2/50µs ≥ 3.6kV |
IEC EN 60 950 |
Surge Current Test |
8/20µs 10kA |
ITU T-K.12 |
|
Environmental
Test Name |
Test Values ∆R |
Norms |
Temperature Cycling |
-40ºC + 70ºC, ≤ 2.5 mΩ |
IEC 60 512 6-11d
IEC 68-2-14-Na |
Temperature Cycling with Humidity |
< 1 mΩ
≤ 2.5 mΩ |
ASTM 539-96
IEC 68-2-3-Ca |
H2S - Industry Gas Testing |
< 1 mΩ
≤ 2.5 mΩ |
ASTM 539-96
IEC 68-2-42 |
Salt Fog Exposure |
< 1 mΩ
≤ 2.5 mΩ |
ASTM 539-96
IEC 60-512-6-6
IEC 68-2-11 |
Chemical Resistance |
< 1 mΩ
≤ 2.5 mΩ |
ASTM 539-96
IEC 352-4-12 |
Insertion Loss
Test Name |
Test Values |
DIN EN 50173
|
Frequency (MHz) |
CAT 5 120Ω
dB |
1 |
≤ 0.1 |
4 |
≤ 0.1 |
10 |
≤ 0.1 |
16 |
≤ 0.2 |
20 |
≤ 0.2 |
31.25 |
≤ 0.2 |
62.5 |
≤ 0.3 |
100 |
≤ 0.4 |
Near-End Cross Talk
Test Name |
Test Values |
DIN EN 50173
|
Frequency (MHz) |
CAT 5 120Ω
dB |
1 |
≤ - 65 |
4 |
≤ - 65 |
10 |
≤ - 60 |
16 |
≤ - 56 |
20 |
≤ - 54 |
31.25 |
≤ - 50 |
62.5 |
≤ - 44 |
100 |
≤ - 40 |
Return Loss
Test Name |
Test Values |
DIN EN 50173
|
Frequency (MHz) |
CAT 5 120Ω
dB |
> 1.0 MHz |
≤ - 23 |
< 20 |
≤ - 23 |
≥ 20 |
≤ - 14 |
≤100 |
≤ - 14 |
|
|
For further information please contact support@kunt.com.tr
|
|
|
|