Products
|
|
Blocks Yak - 20 / 100 pair Terminal Block |
|
|
|
Technical Specification
Mechanical |
Test Name |
Test Requirements |
Tensile |
0.35mm / >20 N (Vertical) / > 3N (Horizontal) |
|
0.50mm / >40 N (Vertical) / > 6N (Horizontal) |
|
0.60mm / >50 N (Vertical) / > 8N (Horizontal) |
Torsion |
0,4 mm copper conductor 5 N
0,5 mm copper conductor 7 N
0,6 mm copper conductor 8 N |
Bending |
10 x 180° |
|
|
Electrical |
Test Name |
Test Requirements |
Connection Resistance |
≤ 2.5m Ω |
Vibration |
≤ 2m Ω |
Insulation Resistance (High Humidity) |
> 50,000 MΩ |
Insulation Resistance (Water Immersion) |
- |
Dielectric Strength |
≥ 2 kVAC 60 sec. |
High Voltage Surge |
10 / 700 µsec ≥ 5 kV |
Surge Current Test |
8 / 20 µsec. 10kA |
|
|
Environmental |
Test Name |
Test Requirements |
Temperature Cycling |
≤ 2 mΩ |
Temperature Cycling with Humidity |
≤ 2 mΩ |
H2S - Industry Gas Testing |
≤ 2 mΩ |
Stress Relaxation |
- |
Salt Fog Exposure |
≤ 2 mΩ |
Chemical Resistance |
≤ 2 mΩ |
|
|
|
|
For further information please contact support@kunt.com.tr
|
|
|
|